top of page
Fixing Electricity Lines

Ceasefire's Globally Certified
In-Panel Fire Suppression Systems 

Ideally suited to fire proof electrical panels, CNC Machines, Wind Turbines, Engine Compartments or any  enclosed space that needs fire protection.

Screenshot 2022-12-21 at 1.56.16 PM.png

Introducing Ceasefire's Quick Response System, a revolutionary firefighting solution which combines ground-breaking technology with functional simplicity to keep what's precious, safe. The most prominent feature of the Ceasefire Quick Response System is the specially designed heat-sensitive pneumatic polymer tubing. It is connected at one end to a Ceasefire extinguishing agent container, while the rest of it runs unobtrusively throughout the area at risk.

 

In case of a fire the heat sensing tube senses an increase in temperature (150° - 180°C) and bursts on coming in contact with flames activating the system automatically. The system has two prime variants - Direct & Indirect. In the direct configuration of the system the bursting of the tube triggers the valve of the extinguisher to spray the extinguishing agent out of the tube directly onto the flame, dousing the fire instantaneously.  In the indirect configuration the bursting of the tube triggers the valve to expel the agent through a separate discharge line onto the fire leading to total flooding inside the cabinet. Direct systems are suitable for compartmentalised cabinets, whereas the Indirect system is perfect for non-compartmentalised cabinets.  

Wide variety of extinguishing agents for wider applications to protect most diverse kind of spaces.

The system comes in a host of extinguishing agents like ABC MAP90 Powder, Fluoroketone (FK), Foam in Low Pressure and CO2 in High Pressure technology, making the system highly versatile and applicable to a large number of spaces.

CQRS Family.png

CUSTOM MADE SOLUTIONS FOR COMPLETE PEACE OF MIND

Screenshot 2022-08-31 at 12.10.53 PM.png
Screenshot 2022-08-31 at 12.11.06 PM.png

In the Direct System the heat-sensitive tubing acts as an extinguishing agent delivery system. The tube bursts at the point where the fire is detected, forms a miniature nozzle and sprays the extinguishing agent. Ideal for places where fires can break out in localised areas. This is available in low-pressure and high-pressure systems.

In the Indirect system, the heat-sensitive tubing only acts as a detection device. The extinguishing agent is delivered through a steel conduit and sprayed across the entire area through strategically placed nozzles. Ideal for areas where there is a chance of fires igniting at multiple points. This is available in low-pressure and high-pressure systems.

Why Ceasefire
In-panel Systems?

Screenshot 2022-08-31 at 6.28.25 PM.png
  • Every Ceasefire In-panel system is designed and configured with precision for the space it is installed in by our in-house Design Cell comprising of expert designers and fire experts. 

  • The Direct system in 2Kg, 3Kg and 4Kg sizes in Fluoroketone (FK) Clean Agent, is fully certified by LPCB under LPS 1666 and the system's design and installation fully adheres to the guidelines laid down as per the standard.

  • The system is LPCB certified for application in enclosed spaces with provision for both, Natural Air Flow and Forced Air Flow.  

  • BSI tested for all system variants

  • High grade TPED certified brass / stainless steel valve with an in-built ball valve that has no chance of accidental activation or closure of the system.

  • Open / close position of the valve can be monitored electronically on the Control Panel.

  • System deploys a UL certified, high grade polyamide, multilayered Heat Sensing Tube with improved burst characteristics that is UV protected for long life in harshest of conditions.

  • High quality connectors for pressurised fittings. 

  • State-of-the-art Control Panel capable of monitoring upto 4 cylinder systems which reads the valve position and pressure switches status and gives a ready health check of the system on the screen. In-built 24 hour battery back up and a large user friendly LCD display.

  • Classification: Fights Class A, B, C and Electrically started fires. 

 

  • Application: Ideal for places where fires can break out in localised areas.

 

  • Self – Contained: Does not require any power supply and will function normally in the event of a power outage.

  • Wide Choice of agents: The system comes in a host of extinguishing agents like ABC MAP90 Powder, Fluoroketone (FK), Foam in Low Pressure and CO2 in High Pressure technology, making the system highly versatile and applicable to a large number of spaces.

 

  • Instant self-activation: Eliminating the need for human intervention, the system is in a perpetual state of readiness to combat a fire as soon as it breaks out.

  

  • Extended Reach: Flexible tubing extends protection to areas that are difficult to access and may not be able to accommodate any other means of detection.

 

  • Easy Installation: Simple design, and can be installed within a few hours, which means a significant reduction in labour costs and downtime.

  • Rugged Design: Can withstand even harsh conditions where other types of detection systems might be rendered inadequate.

  

  • Swift and Comprehensive: Running intricately and unobtrusively through servers, gensets,CNC machines, and electrical mains boxes, the system can be triggered instantly and automatically. This eliminates the need for human intervention and provides a swift and comprehensive solution.

 

  • Certification: BSI tested, LPCB, UL, and CE certified.

CQRS Range

PRODUCT APPLICATIONS

At Ceasefire, We've segregated our fire solutions by application areas to make it easier for you to find the ones that fit your premises and your requirements.

Servers
Fixing Electricity Lines
Wind Turbines
Plotter
Engine
BATTERY-BANK.jpeg
fume.jpeg
generator-rental-service-500x500.webp